Glynn-Johnson offers a complete line of overhead door holders and stops, accommodating virtually all openings with solutions for even the most complex door control problems. These concealed holders and stops provide the most attractive and reliable heavy-duty door control available.
Glynn-Johnson 100 series holders and stops provide the most reliable and versatile concealed overhead door control. They are designed for installation on virtually all types of doors mounted on conventional type butt hinges, pivots, continuous hinges, swing clear hinges and numerous other specialty hinges. When used in conjunction with many surface-applied door closers, 100 series holders and stops provide the most effective control for entrance doors and vestibule doors of all types, as well as heavy or often used interior doors. Templates provided allow for variable mounting positions, ranging from 85° - 110° of opening.
Five Models:
100H Series Hold-Open Model 100HP Series Internal Hold-Open Model 100F Series Friction Hold-Open Model 100S Series Stop-Only Model 100SE Series Special Stop-Only Model
Six Sizes:
Each model comes in six sizes. Simple Standardized
Three Options:
ADJ-Adjustable Jamb Bracket CJ-Jamb Bracket for use with LCN5030 Closer SOC-Pin-in-Socket Security Screw Package
(Suffix F) Friction Hold-Open models provide an alternative holding method, ideal for heavy patient room doors, closet doors or similar applications where multiple Hold-Open positions are desired. The friction tension is adjusted using an allen wrench and an open end wrench. The friction tension adjustment is located on the top of the slider in the channel.
Finishes:
US32 - Polished Stainless Steel
- Application Information
- UL Classification
- The 100 series Stop-Only models are classified by Underwriters Laboratories (UL) as Miscellaneous Fire Door Accessories. This classification applies to use on either Hollow Metal Fire Doors or Wood Fire Doors. Where Wood Door manufacturer’s listing allows for the cutout required for installation, concealed overhead stops may be used on those wood fire doors. These units may be used on doors of any rating. As a reminder, the Miscellaneous Fire Door Accessories (GVUX) section is defined by UL as: "Miscellaneous fire door accessories are intended in the individual Listings. The accessories have been investigated to determine that when installed in accordance with the manufacturer's instructions, the accessories do not adversely affect the fire rating of the fire door and/or fire door frames."
- Dead Stop Templating:
- If a wall or similar obstruction is in place at 110° or less opening angle (i.e. doors that open back-to-back), Dead Stop Templating should be used. This includes all Hold-Open, Friction and Stop-Only models, except when the "SE" Option is used. The Dead Stop position is reached when the shock-absorbing spring is fully compressed, the initial degree of opening will be 5° to 7° less than the Dead Stop opening. Example: If the holder is templated to 100° Dead Stop, the door will hold open somewhere between 93° and 95°, but no further than 100°
- Note: Do not use dead-stop templating on the 100SE Series since there is no shock-absorbing spring.
- Environmental Considerations:
- Environmental factors should always be considered when specifying overhead holders and stops. Doors that are positioned on a building’s exterior or subject to corrosive conditions should be equipped with a holder constructed primarily of stainless steel or brass materials. For interior applications, steel is acceptable, though brass substrates generally provide a more attractive architectural-grade finish.
- Function Conversion Kits
- FK100F-Converts a 100H or 100S unit into a 100F unit.
- To order specify FK100F.
- FK100H-Converts a 100F or 100S unit into a 100H unit.
- To order specify FK100H.
- No kit is needed to convert a 100H or 100F unit into a 100S unit.
- Options
- Suffix ADJ (Adjustable Jamb Bracket):
- An additional option on the 100 series is the adjustable jamb bracket, which allows the degree of Hold-Open or Stop angle to be adjusted after installation. Suffix "ADJ” is available in all functions, but only in sizes 3, 4, 5 & 6. ADJ jamb bracket requires additional frame prep. The ADJ option cannot be added to an existing unit, it must be factory ordered.
- Suffix CJ (Closer Jamb Bracket):
- Provides a special jamb bracket needed for 100 series units used with LCN5030 closers. These special jamb brackets are handed, so handing will need to be specified when ordering the "CJ” option, CJLH for a left hand door and CJRH for a right hand door. The CJ option cannot be added to an existing unit, it must be factory ordered.
- Suffix SOC (Pin-in-Socket Security Screw Package):
- A screw package with pin-in-socket screws for mounting the jamb bracket to the frame is provided instead of the standard screw package.
|
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Features
- Non-handed
- Improved Compatibility with Door Closers
- Single/Double-Acting Doors
- Interior/Exterior Applications
- Reduced Door Prep
- Durable
- Improved Corrosion Resistance
- Function Conversion Kits are Available.
|
|
 |
 |
 |
 |
|
 |

|